ACS TURN
For High to Very High Risk
Contact Us For More Info
Continuous Lateral Rotation Mattress with True Low Air Loss.
Prevention of Ventilator-associated Pneumonia
- Suitable for patients in very high risk of pressure injuries
- Up to 40° continuous lateral rotation to improve secretion clearance
- True low air loss therapy offers better skin microclimate management
- Designed for use in the acute care sector
Low Air Loss Turning Air Mattress
- Suitable for patients in high to very high risk of pressure injuries.
- Up to 40° continuous lateral rotation to improve secretion clearance.
- True low air loss therapy offers better skin microclimate management.
- Designed for use in the acute care sector.
Drainage Tubing Placement-Placement allows drainage tubing to pass through easily.
Turning Options-Selectable turning angles and dwell times can be tailored to meet patient's individual need.
Reserved 2" foam base pocket and 10" side bolster for additional patient's safety- Better skin microclimate management to minimise tissue deformation and prevent skin breakdown.
Easy-to-use CPR Connector - CPR < 15 seconds.
| Pump | |
|---|---|
| Dimension | 15.8 x 38 x 26.8 cm |
| Weight | 6 kg |
| Case Material | Flame retardant ABS |
| Supply Voltage | AC 220 - 240V, 50Hz |
| Operating Cycle | Dwell Time 5, 30, 60 mins |
| Air Output (lpm) | Maximum airflow 1,300 liter/mins |
| Mattress | |
|---|---|
| Type | 8"+2" Replacement |
| Dimension | 200 x 90 x 25.4 (H8") |
Cell Height | 20 x 8" ; 2 x 10" (side bolster) |
| Weight | 10.1 kg |
| Cover Material | Nylon / PU |
| CPR | At the quick connector |
| Maximum Patient Weight | 180 kg |
| Flame Retardant | EN 597-1 & EN 597-2 |
Low Air Loss Turning Air Mattress
- Suitable for patients in high to very high risk of pressure injuries.
- Up to 40° continuous lateral rotation to improve secretion clearance.
- True low air loss therapy offers better skin microclimate management.
- Designed for use in the acute care sector.
Drainage Tubing Placement-Placement allows drainage tubing to pass through easily.
Turning Options-Selectable turning angles and dwell times can be tailored to meet patient's individual need.
Reserved 2" foam base pocket and 10" side bolster for additional patient's safety- Better skin microclimate management to minimise tissue deformation and prevent skin breakdown.
Easy-to-use CPR Connector - CPR < 15 seconds.
Reference
- Prevention of ventilator-associated pneumonia in the ICU: Beyond the basics. JONN. 2016.
- Van Nieuwenhoven, C. A., E. Buskens, D. C. Bergmans, F. H. van Tiel, G. Ramsay, and M. J. Bonten. 2004. Oral decontamination is cost-saving in the prevention of ventilator-associated pneumonia in intensive care units. Crit. Care Med. 32:126-130.
- Wilson, D. et al., Wong's Clinical Manual of Paediatric Nursing-E-Book. Elsevier Health Sciences, 2014.
